Master’s Research Paper Presentation • Bioinformatics • Does Injecting Biology Help? Mechanistic Knowledge Improves Proarrhythmia Prediction Only When Channel Potencies Are Measured

Monday, December 7, 2026 12:00 pm - 1:00 pm EST (GMT -05:00)

Please note: This master’s research paper presentation will take place in DC 3317.

Jacie Jermier, Master’s candidate
David R. Cheriton School of Computer Science

Supervisors: Professors Helen Chen, Anita Layton

Mechanistic models of the cardiac action potential are increasingly combined with machine learning to predict a drug’s risk of causing Torsades de Pointes. The usual framing asks how deeply the mechanism should be built in, whether through features, architecture, loss, or a differentiable simulator. A comparison of those depths on one 55-drug panel under one protocol shows that depth was not what decided the outcome. Whether the channel potencies were measured or predicted did. With measured IC50 values, a single simulator derived number, qNet, reaches AUC 0.920 against 0.803 for hERG block alone. The paired difference is +0.117 with a 95% interval of +0.040 to +0.212. It corrects 62 percent of the pairs the single-channel screen orders wrongly and breaks none of the 40 drugs that screen already calls correctly. With IC50 values predicted from molecular structure, qNet falls to 0.535, and every mechanistic arm is beaten by predicted hERG potency alone at 0.783. Swapping in a stronger front end lifts every arm without changing the picture. qNet reaches 0.647 while raw predicted potency reaches 0.817, so the simulator still loses to the input it is given. The degradation is ordered, and the deeper the score the more it loses. There is an error level at which qNet stops beating raw potency, and under injected noise it sits at 0.30 to 0.35 log10 units per channel. That is a lower bound. Real model error is structured rather than random, and at the same magnitude it costs qNet a further 0.094 to 0.206 AUC depending on the front end. Public structure-based models sit on the wrong side of this threshold. And so does the assay they would have to learn from. Two laboratories measuring the same drug on the same channel agree only to within 0.38 to 0.47 log10 units, which is a factor of two to three in potency. The pipeline needs 0.30 to 0.35 at best, so the quantity is not reproducible to the accuracy the method requires. The conclusion is conditional and measurable. Injecting biology helps, and it helps broadly rather than only in a hard subgroup, but only when the parameters feeding it are measured rather than predicted.