Notes for the
MegaRaid Command Line Interface
References
MegaRaid Hardware Documents
Get raid controller log
- MegaCli64 -adpeventlog -getevents -f lsi-events.log -a0 -nolog
Raid Controller and Drive Status
-
- /opt/MegaRAID/MegaCli/MegaCli -LDInfo -LAll -aAll -a0
root@scspcxxx:~# /opt/MegaRAID/MegaCli/MegaCli -LDInfo -LAll -aAll
Adapter 0 -- Virtual Drive Information:
Virtual Drive: 0 (Target Id: 0)
Name :
RAID Level : Primary-6, Secondary-0, RAID Level Qualifier-3
Size : 3.635 TB
Is VD emulated : No
Parity Size : 3.635 TB
State : Optimal
Strip Size : 64 KB
Number Of Drives : 4
Span Depth : 1
Default Cache Policy: WriteBack, ReadAhead, Cached, Write Cache OK if Bad BBU
Current Cache Policy: WriteBack, ReadAhead, Cached, Write Cache OK if Bad BBU
Default Access Policy: Read/Write
Current Access Policy: Read/Write
Disk Cache Policy : Enabled
Encryption Type : None
Bad Blocks Exist: No
Is VD Cached: No
Virtual Drive: 1 (Target Id: 1)
Name :
RAID Level : Primary-1, Secondary-0, RAID Level Qualifier-0
Size : 1.817 TB
Is VD emulated : Yes
Mirror Data : 1.817 TB
State : Optimal
Strip Size : 64 KB
Number Of Drives : 2
Span Depth : 1
Default Cache Policy: WriteBack, ReadAhead, Cached, Write Cache OK if Bad BBU
Current Cache Policy: WriteBack, ReadAhead, Cached, Write Cache OK if Bad BBU
Default Access Policy: Read/Write
Current Access Policy: Read/Write
Disk Cache Policy : Enabled
Encryption Type : None
Bad Blocks Exist: No
Is VD Cached: No
Virtual Drive: 2 (Target Id: 2)
Name :
RAID Level : Primary-1, Secondary-0, RAID Level Qualifier-0
Size : 930.390 GB
Is VD emulated : No
Mirror Data : 930.390 GB
State : Optimal
Strip Size : 64 KB
Number Of Drives : 2
Span Depth : 1
Default Cache Policy: WriteBack, ReadAhead, Cached, Write Cache OK if Bad BBU
Current Cache Policy: WriteBack, ReadAhead, Cached, Write Cache OK if Bad BBU
Default Access Policy: Read/Write
Current Access Policy: Read/Write
Disk Cache Policy : Enabled
Encryption Type : None
Bad Blocks Exist: No
Is VD Cached: No
List any drive errors, warnings etc
- /MegaCli64 -CfgDsply -a0 | grep -ie "fail\|error\|inquiry\|\warn\|s.m.a.r.t."
List Disk Groups and Disks
- ./MegaCli64 -CfgDsply -a0
List drives by Enclosure Device ID and Slot Number
- MegaCli64 -PDList -a0|grep -E 'Inquiry|Firmware|Slot|ID'
Autorebuild Status
Query Rebuild Rate
Enable Disk Drive Cache
- /opt/MegaRAID/MegaCli/MegaCli -LDSetProp -EnDskCache -Immediate -LAll -aAll
root@scspcxxx:~# /opt/MegaRAID/MegaCli/MegaCli -LDSetProp -EnDskCache -Immediate -LAll -aAll
Set Disk Cache Policy to Enabled on Adapter 0, VD 0 (target id: 0) success
Set Disk Cache Policy to Enabled on Adapter 0, VD 1 (target id: 1) success
Set Disk Cache Policy to Enabled on Adapter 0, VD 2 (target id: 2) success
Exit Code: 0x00
Enable Read-Ahead
- /opt/MegaRAID/MegaCli/MegaCli -LDSetProp -RA -Immediate -LALL -aALL
* root@scspcxxx:~# /opt/MegaRAID/MegaCli/MegaCli -LDSetProp -RA -Immediate -LALL -aALL
Set Read Policy to ReadAhead on Adapter 0, VD 0 (target id: 0) success
Set Read Policy to ReadAhead
./MegaCli64 -CfgDsply -a0 on Adapter 0, VD 1 (target id: 1) success
Set Read Policy to ReadAhead on Adapter 0, VD 2 (target id: 2) success
Exit Code: 0x00
Enable Write Back Cache on Raid Cntroller
- */opt/MegaRAID/MegaCli/MegaCli -LDSetProp WB -LALL -aALL *
Check Battery Status
Force Battery Learn Cycle
- /opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -BbuLearn -aALL
Disable Write Cache if battery is bad
- MegaCli64 -LDSetProp -NoCachedBadBBU -Immediate -Lall -aAll
Enable Write Back Cache even if Battery is dead or missing
- root@scspcxxx:~# /opt/MegaRAID/MegaCli/MegaCli64 -LDSetProp -CachedBadBBU -Immediate -Lall -aAll
root@scspcxxx:~# /opt/MegaRAID/MegaCli/MegaCli64 -LDSetProp -CachedBadBBU -Immediate -Lall -aAll
Set Write Cache OK if bad BBU on Adapter 0, VD 0 (target id: 0) success
Set Write Cache OK if bad BBU on Adapter 0, VD 1 (target id: 1) success
Set Write Cache OK if bad BBU on Adapter 0, VD 2 (target id: 2) success
Exit Code: 0x00
Check NCQ status
Finding faulty drive
Start Blink LED on srive
- MegaCli64 -PdLocate -start -physdrv[252:0] -aALL
-
- Note: Enclosure ID: 252, Slot: 0
Stop Blink LED on srive
- MegaCli64 -PdLocate -start -physdrv[252:0] -aALL
- Note: Enclosure ID: 252, Slot: 0
Contoller Information
- MegaCli/MegaCli64 -adpallinfo -a0
Silence Alarms
Take drive offline
*MegaCli/MegaCli64 -PDOffline -PhysDrv [252:3] -a0
-
- Note: * Note: *Enclosure ID: 252, Slot: 3*
Verify drive state
- MegaCli64 -PdInfo -PhysDrv 252:3] -a0 | grep state
- Note: * Note: *Enclosure ID: 252, Slot: 3*
Example finding failed disk and blinking the led on it
- List Drive status - see listing below for output for this example
- Blink Failing drive
- Note looking at the listing below you will see the following information on the bad drive
- Enclosure Device ID: 252
- Slot Number: 0
- Enclosure position: 0
- MegaCli64 -PdLocate -start -physdrv[252:0] -aALL
- We used Enclosure Device ID: 252 and Slot Number: 0
MegaCli64 -CfgDsply -a0
==============================================================================
Adapter: 0
Product Name: LSI 2108 MegaRAID
Memory: 512MB
BBU: Present
Serial No:
==============================================================================
Number of DISK GROUPS: 3
DISK GROUP: 0
Number of Spans: 1
SPAN: 0
Span Reference: 0x00
Number of PDs: 4
Number of VDs: 1
Number of dedicated Hotspares: 0
Virtual Drive Information:
Virtual Drive: 0 (Target Id: 0)
Name :
RAID Level : Primary-6, Secondary-0, RAID Level Qualifier-3
Size : 3.635 TB
State : Optimal
Strip Size : 64 KB
Number Of Drives : 4
Span Depth : 1
Default Cache Policy: WriteBack, ReadAhead, Cached, Write Cache OK if Bad BBU
Current Cache Policy: WriteBack, ReadAhead, Cached, Write Cache OK if Bad BBU
Access Policy : Read/Write
Disk Cache Policy : Enabled
Encryption Type : None
Bad Blocks Exist: No
Physical Disk Information:
Physical Disk: 0
Enclosure Device ID: 252
Slot Number: 0
Enclosure position: 0
Device Id: 5
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 1
Last Predictive Failure Event Seq Number: 347191
PD Type: SAS
Raw Size: 1.819 TB [0xe8e088b0 Sectors]
Non Coerced Size: 1.818 TB [0xe8d088b0 Sectors]
Coerced Size: 1.817 TB [0xe8b6d000 Sectors]
Firmware state: Online, Spun Up
SAS Address(0): 0x5000c50025e6fbb1
SAS Address(1): 0x0
Connected Port Number: 0(path0)
Inquiry Data: SEAGATE ST32000444SS 00069WM345GE
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None
Device Speed: 6.0Gb/s
Link Speed: 6.0Gb/s
Media Type: Hard Disk Device
Drive: Not Certified
Drive Temperature :44C (111.20 F)
Physical Disk: 1
Enclosure Device ID: 252
Slot Number: 1
Enclosure position: 0
Device Id: 6
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SAS
Raw Size: 1.819 TB [0xe8e088b0 Sectors]
Non Coerced Size: 1.818 TB [0xe8d088b0 Sectors]
Coerced Size: 1.817 TB [0xe8b6d000 Sectors]
Firmware state: Online, Spun Up
SAS Address(0): 0x5000c50062bcffb1
SAS Address(1): 0x0
Connected Port Number: 6(path0)
Inquiry Data: SEAGATE ST2000NM0023 0004Z1X3KAP4
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None
Device Speed: 6.0Gb/s
Link Speed: 6.0Gb/s
Media Type: Hard Disk Device
Drive: Not Certified
Drive Temperature :45C (113.00 F)
Physical Disk: 2
Enclosure Device ID: 252
Slot Number: 2
Enclosure position: 0
Device Id: 7
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SAS
Raw Size: 1.819 TB [0xe8e088b0 Sectors]
Non Coerced Size: 1.818 TB [0xe8d088b0 Sectors]
Coerced Size: 1.817 TB [0xe8b6d000 Sectors]
Firmware state: Online, Spun Up
SAS Address(0): 0x5000c50062bd14cd
SAS Address(1): 0x0
Connected Port Number: 1(path0)
Inquiry Data: SEAGATE ST2000NM0023 0004Z1X3KA7L
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None
Device Speed: 6.0Gb/s
Link Speed: 6.0Gb/s
Media Type: Hard Disk Device
Drive: Not Certified
Drive Temperature :44C (111.20 F)
Physical Disk: 3
Enclosure Device ID: 252
Slot Number: 3
Enclosure position: 0
Device Id: 8
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SAS
Raw Size: 1.819 TB [0xe8e088b0 Sectors]
Non Coerced Size: 1.818 TB [0xe8d088b0 Sectors]
Coerced Size: 1.817 TB [0xe8b6d000 Sectors]
Firmware state: Online, Spun Up
SAS Address(0): 0x5000c50025e5fad5
SAS Address(1): 0x0
Connected Port Number: 3(path0)
Inquiry Data: SEAGATE ST32000444SS 00069WM33DYT
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None
Device Speed: 6.0Gb/s
Link Speed: 6.0Gb/s
Media Type: Hard Disk Device
Drive: Not Certified
Drive Temperature :39C (102.20 F)
DISK GROUP: 1
Number of Spans: 1
SPAN: 0
Span Reference: 0x01
Number of PDs: 2
Number of VDs: 1
Number of dedicated Hotspares: 0
Virtual Drive Information:
Virtual Drive: 1 (Target Id: 1)
Name :
RAID Level : Primary-1, Secondary-0, RAID Level Qualifier-0
Size : 1.817 TB
State : Optimal
Strip Size : 64 KB
Number Of Drives : 2
Span Depth : 1
Default Cache Policy: WriteBack, ReadAhead, Cached, Write Cache OK if Bad BBU
Current Cache Policy: WriteBack, ReadAhead, Cached, Write Cache OK if Bad BBU
Access Policy : Read/Write
Disk Cache Policy : Enabled
Encryption Type : None
Bad Blocks Exist: No
Physical Disk Information:
Physical Disk: 0
Enclosure Device ID: 252
Slot Number: 4
Enclosure position: 0
Device Id: 10
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SATA
Raw Size: 1.819 TB [0xe8e088b0 Sectors]
Non Coerced Size: 1.818 TB [0xe8d088b0 Sectors]
Coerced Size: 1.817 TB [0xe8b6d000 Sectors]
Firmware state: Online, Spun Up
SAS Address(0): 0x4433221104000000
Connected Port Number: 7(path0)
Inquiry Data: WD-WCAZA8177192WDC WD20EARS-00MVWB0 51.0AB51
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None
Device Speed: 3.0Gb/s
Link Speed: 3.0Gb/s
Media Type: Hard Disk Device
Drive: Not Certified
Drive Temperature :30C (86.00 F)
Physical Disk: 1
Enclosure Device ID: 252
Slot Number: 5
Enclosure position: 0
Device Id: 9
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SATA
Raw Size: 1.819 TB [0xe8e088b0 Sectors]
Non Coerced Size: 1.818 TB [0xe8d088b0 Sectors]
Coerced Size: 1.817 TB [0xe8b6d000 Sectors]
Firmware state: Online, Spun Up
SAS Address(0): 0x4433221105000000
Connected Port Number: 2(path0)
Inquiry Data: WD-WMAZA6728709WDC WD20EARX-00PASB0 51.0AB51
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None
Device Speed: 6.0Gb/s
Link Speed: 6.0Gb/s
Media Type: Hard Disk Device
Drive: Not Certified
Drive Temperature :36C (96.80 F)
DISK GROUP: 2
Number of Spans: 1
SPAN: 0
Span Reference: 0x02
Number of PDs: 2
Number of VDs: 1
Number of dedicated Hotspares: 0
Virtual Drive Information:
Virtual Drive: 2 (Target Id: 2)
Name :
RAID Level : Primary-1, Secondary-0, RAID Level Qualifier-0
Size : 930.390 GB
State : Optimal
Strip Size : 64 KB
Number Of Drives : 2
Span Depth : 1
Default Cache Policy: WriteBack, ReadAhead, Cached, Write Cache OK if Bad BBU
Current Cache Policy: WriteBack, ReadAhead, Cached, Write Cache OK if Bad BBU
Access Policy : Read/Write
Disk Cache Policy : Enabled
Encryption Type : None
Bad Blocks Exist: No
Physical Disk Information:
Physical Disk: 0
Enclosure Device ID: 252
Slot Number: 6
Enclosure position: 0
Device Id: 11
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SATA
Raw Size: 931.512 GB [0x74706db0 Sectors]
Non Coerced Size: 931.012 GB [0x74606db0 Sectors]
Coerced Size: 930.390 GB [0x744c8000 Sectors]
Firmware state: Online, Spun Up
SAS Address(0): 0x4433221106000000
Connected Port Number: 4(path0)
Inquiry Data: WD-WMATV0360069WDC WD1002FBYS-01A6B0 03.00C05
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None
Device Speed: 3.0Gb/s
Link Speed: 3.0Gb/s
Media Type: Hard Disk Device
Drive: Not Certified
Drive Temperature :44C (111.20 F)
Physical Disk: 1
Enclosure Device ID: 252
Slot Number: 7
Enclosure position: 0
Device Id: 4
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SATA
Raw Size: 931.512 GB [0x74706db0 Sectors]
Non Coerced Size: 931.012 GB [0x74606db0 Sectors]
Coerced Size: 930.390 GB [0x744c8000 Sectors]
Firmware state: Online, Spun Up
SAS Address(0): 0x4433221107000000
Connected Port Number: 5(path0)
Inquiry Data: WD-WMATV0407068WDC WD1002FBYS-01A6B0 03.00C05
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None
Device Speed: 3.0Gb/s
Link Speed: 3.0Gb/s
Media Type: Hard Disk Device
Drive: Not Certified
Drive Temperature :46C (114.80 F)