Back to Contents Page

Switch/General/Asset Page:
Dell™ PowerEdge™ 1655MC Integrated Switch User's Guide


Asset Page

The Asset page contains the following information:

* These fields may be edited. (Maximum length: 255 characters)

To save any changes you make, click Apply Changes. To reset these fields to their current value, click Refresh.

CLI Commands

The following is a summary of the equivalent CLI commands for items in the Switch/General/Asset web page.

Command Usage
show system Use this command to display system information. (LINK)
hostname name Use this command to specify or modify the system name for this device. (LINK)
snmp-server contact string Use this command to set the system contact (sysContact) string. (LINK)
snmp-server location text Use this command to set the system location string. (LINK)

Example

(config)#hostname PE 1655MC
(config)#snmp-server contact spk
(config)#snmp-server location R&D
(config)#exit
#show system
System description: PowerEdge 1655MC Integrated Switch
System OID string: 1.3.6.1.4.1.674.10896.1
System information
 System Up time: 0 days, 5 hours, 16 minutes, and 15.54 seconds
 System Name            : PE 1655MC
 System Location        : R&D
 System Contact         : spk
 MAC address            : 22-22-22-22-22-22
 Web server             : enable
 Web server port        : 80
POST result :
Loopback Testing UART Channel ................... PASS
Flash Memory Checksum Test....................... PASS
Testing the System SDRAM ........................ PASS
CPU Self Test ................................... PASS
MPC850 internal clock Timer and Interrupt TEST .. PASS
WatchDog Timer and Interrupt Test ............... PASS
PLX9054 Access Test ............................. PASS
BCM5633 Chip Test ............................... PASS
I2C R/W Test .................................... PASS
SERDES and PHY internal loopback Test............ PASS
#



 Back to Contents Page