Dell PowerEdge 2600 Systems User's Guide
Expansion Bus | |
---|---|
Bus type | PCI/PCI-X |
Expansion slots | six dedicated PCI/PCI-X (full-length, 64-bit, two at 33/66/100/133 MHz, four at 33/66/100 MHz) and one dedicated PCI (32/33 MHz) |
Drives | |
---|---|
Diskette drive | 3.5-inch, 1.44-MB diskette drive |
Hard drives | six 1-inch, internal Ultra320 SCSI |
CD or DVD drive | one IDE CD or DVD drive |
Video | |
---|---|
Video type | ATI Rage XL PCI video controller; VGA connector |
Video memory | 8 MB |
Environmental | |
---|---|
Temperature: |
|
Operating | 10°C to 35°C (50°F to 95°F) |
Storage | 40° to 65°C (40°F to 149°F) |
Relative humidity: |
|
Operating | 20% to 80% (noncondensing) with a maximum humidity gradation of 10% per hour |
Storage | 5% to 95% (noncondensing) with a maximum humidity gradation of 10% per hour |
Maximum vibration: | |
Operating | 0.25 G at 3 to 200 Hz for 15 minutes |
Storage | 0.5 G at 3 to 200 Hz for 15 minutes |
Maximum shock: | |
Operating | one shock pulse in the negative z axis (one pulse on system bottom) of 41 G for up to 2ms |
Storage (non-operational) | six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms |
Altitude: | |
Operating | 16 to 3,048 m (50 to 10,000 ft.) |
Storage | 16 to 10,600 m (50 to 35,000 ft) |
NOTE: For the full name of an abbreviation or acronym used in this table, see the "Glossary." |