Back to Contents Page

Result Codes: Multi-Tech MT5634ZBA User's Guide


In command mode your modem can send responses called result codes to your computer. Result codes are used by communications programs and can also appear on your monitor.

Terse Verbose Description
0 OK Command executed
1 CONNECT Modem connected to line
2 RING Ring signal detected
3 NO CARRIER Carrier signal lost or not detected
4 ERROR Invalid command
5 * CONNECT 1200 Connected at 1200 bps
6 NO DIALTONE No dial tone detected
7 BUSY Busy signal detected
8 NO ANSWER No answer at remote end
10 * CONNECT 2400 Connected at 2400 bps
11 * CONNECT 4800 Connected at 4800 bps
12 * CONNECT 9600 Connected at 9600 bps
13 * CONNECT 14400 Connected at 14400 bps
14 * CONNECT 19200 Connected at 19200 bps
24 * CONNECT 7200 Connected at 7200 bps
25 * CONNECT 12000 Connected at 12000 bps
26 * CONNECT 16800 Connected at 16800 bps
40 * CONNECT 300 Connected at 300 bps
55 * CONNECT 21600 Connected at 21600 bps
56 * CONNECT 24000 Connected at 24000 bps
57 * CONNECT 26400 Connected at 26400 bps
58 * CONNECT 28800 Connected at 28800 bps
59 * CONNECT 31200 Connected at 31200 bps
60 * CONNECT 33600 Connected at 33600 bps
70 * CONNECT 32000 Connected at 32000 bps, K56flex rate
71 * CONNECT 34000 Connected at 34000 bps, K56flex rate
72 * CONNECT 36000 Connected at 36000 bps, K56flex rate
73 * CONNECT 38000 Connected at 38000 bps, K56flex rate
74 * CONNECT 40000 Connected at 40000 bps, K56flex rate
75 * CONNECT 42000 Connected at 42000 bps, K56flex rate
76 * CONNECT 44000 Connected at 44000 bps, K56flex rate
77 * CONNECT 46000 Connected at 46000 bps, K56flex rate
78 * CONNECT 48000 Connected at 48000 bps, K56flex rate
79 * CONNECT 50000 Connected at 50000 bps, K56flex rate
80 * CONNECT 52000 Connected at 52000 bps, K56flex rate
81 * CONNECT 54000 Connected at 54000 bps, K56flex rate
82 * CONNECT 56000 Connected at 56000 bps, K56flex rate
88 DELAYED Delay is in effect for the dialed number
89 BLACKLISTED Dialed number is blacklisted
90 BLACKLIST FULL Blacklist is full
100 * CONNECT 28000 Connected at 28000 bps, V.90 rate
101 * CONNECT 29333 Connected at 29333 bps, V.90 rate
102 * CONNECT 30666 Connected at 30666 bps, V.90 rate
103 * CONNECT 33333 Connected at 33333 bps, V.90 rate
104 * CONNECT 34666 Connected at 34666 bps, V.90 rate
105 * CONNECT 37333 Connected at 37333 bps, V.90 rate
106 * CONNECT 38666 Connected at 38666 bps, V.90 rate
107 * CONNECT 41333 Connected at 41333 bps, V.90 rate
108 * CONNECT 42666 Connected at 42666 bps, V.90 rate
109 * CONNECT 45333 Connected at 45333 bps, V.90 rate
110 * CONNECT 46666 Connected at 46666 bps, V.90 rate
111 * CONNECT 49333 Connected at 49333 bps, V.90 rate
112 * CONNECT 50666 Connected at 50666 bps, V.90 rate
113 * CONNECT 53333 Connected at 53333 bps, V.90 rate
114 * CONNECT 54666 Connected at 54666 bps, V.90 rate

* EC is added to these result codes when the extended result codes option is enabled. EC is replaced by one of the following codes, depending on the type of error control connection:
V42bis —V.42 error control (LAP-M) and V.42bis data compression
V42 —V.42 error control (LAP-M) only
MNP5 —MNP 4 error control and MNP 5 data compression
MNP4 —MNP 4 error control only
NoEC —No error control protocol.


Back to Contents Page